Navigation


Plant Information System

Alarm Notification

  • Inputs
    • Can collect the data from serial alarm printing.
    • Can collect the data from OPC DA Interface.
    • Can collect the data from OPC A & E interface.
    • Can collect the data from Modbus Serial or Modbus TCP/IP protocol interface.
    • Can incorporate modbus IO module with redundant provision to improve the reliability of system and sure-delivery of alert regardless of status of main control system.
  • Software
    • Whole web based interface for management and day to day usage.
    • No-limitation on no. of users/groups, Input channels
  • Processing
    • N-Nos. of alarms (i.e. LOLO, LO, HI, HIHI – 4 limits) can be defined on Analog Points (OPC DA/ Modbus) where each alarm can be configured to send separate message to particular user or groups.
    • Possibility to configure name of On/Off state (i.e. Fail/fault/trip etc) and can be configured to send to particular user or group.
    • Possibility to configure logical combination of current values and alarms with time duration to generate new alarms. i.e. user can configure that if alarm A comes and Alarm B comes within X minutes then send the SMS to group “Site In-charge”.
    • Alarms received from Serial Channel or OPC A&E can be directly configured to pass to particular group or users.
    • Possibility to configure each alert message with
      • Send to current Shift
      • Send to General Shift
      • Send to particular group regardless of shift
      • Send to particular person
      • Send to particular phone number
      • Voice message or SMS
      • Critical flag (Whether to bypass holiday and weekly off flags)
    • Inward Dialing for Voice Call
      • System provides inward dialing number with automated voice system to provide the current status of system through configurable menu.
      • User can dial the number and with authentication based on calling no / auth code, user will be presented the voice menu to provide the status of system.
    • Inward Dialing for SMS
      • System provides the facility to provide the on-demand status using SSM. To get the current status of particular point, user need to send SMS with point / tag no and system will send the return SMS with current value and alarm associated with it.
    • Periodic reporting with scheduling
      • Periodic reporting with following feature can be configured
        • On-line parameters + Static text to be send
        • Group or users to whom message to send
        • Schedule times
          • Particular durations i.e. from 7 Hrs to 15 Hrs.
          • Particular time instance i.e. 6:00,6:30,7:00 Hrs.
          • Every Shift, day, week, month except holiday.
    • Meeting Confirmation:
      • SMS messages can be send to particular group with message and marking so that user can confirm the meeting acceptance with reply SMS. Replay code can be configured that for confirmation – No SMS for decline-Send No in SMS.
      • All the reply will be shown on web based interface for confirmation to user who has planned the meeting.
    • Bulk SMS
      • In critical time, system have single click job defined with predefined message and group/users so that operator can immediately send the SMS to concern to seek the help. Groups can be dynamic where selection of group based on current shift schedule entered.
      • Web interface to send SMS to group of people or list of phone numbers.
    • Users and Groups
      • User can be defined with following attributes
        • Name
        • Designation
        • Can Receive Messages
        • Can Inquire Status
        • Authorization to send bulk SMS through web interface.
        • Primary Mobile No:
        • Secondary Mobile No:
        • Home Telephone No:
        • o Holiday Telephone Nos:
      • Groups can be defined with following attributes
        • Group Name
        • List of Users inside this group.
      • Shift Schedule and Holidays
        • Shift schedule for 4 shifts in day to assign groups with weekly offs.
        • Provision to mark holidays
        • Shift can be adjusted by individual of shift in-charge with proper authentication.



News

  • SSM Infotech bagged an Alarm Management Project for KCM Zambia
  • SSM Infotech Executed Management Information System(MIS) Project for Lanco
  • SSM Infotech bagged GPS Project for Reliance from M/S Yokogawa.
  • SSM Infotech executed GAIL USAR Alarm Management Project.
  • SSM Infotech bagged an Alarm Management Project for ONGC Uran.
  • SSM Infotech bagged an Energy Management Project from Ultratech.
  • SSM Infotech Executed NTPC Alarm Management, Historian, LVS Project for Invensys
  • SSM Infotech bagged an Alarm Management Project for HPCL Vizag.
  • SSM Infotech bagged GPS Project for Lanco from M/S Emerson.
  • SSM Infotech executed Enterprise Alarm Management Project at Reliance.
  • SSM Infotech bagged an Alarm Management Project for IOCL Barouni.
  • SSM Infotech bagged an Energy Management Project from Welspun.
  • SSM Infotech bagged an Alarm Management Project for OPAL from M/S Honeywell.

More Info

Software